EW3391
Overview · Pad A · East Webb
Rod pump
Normal
Live · updated 08:36:17
Oil rate (VFM)
74bbl/d
76% water cut
Liquid rate (VFM)
310bbl/d
Gas 40 Mcf/d
Strokes per minute
6.0SPM
Stroke length 120 in
Pump fillage
82%
Minimum 55 %
Peak rod load
18.1klbs
Limit 24 klbs
Motor current
21.9A
Alarm 30 A
Health
NormalActive alarms
EventsNo active alarms on this well.
Optimization
OpenStrokes per minute
6.0 SPM → 6.8 SPM
Predicted change +2 bbl/d · nothing is applied until approved.
PlexPilot insight
AssistantNo anomalies on EW3391. All signals are inside their normal bands and the health score is 84.
Live operation
Dynamometer cards · surface and pump
Latest stroke, updated each cyclePumping unit
Strokes per minute6.0
Effective pump stroke82 %
Peak rod load18.1 klbs
Fluid poundNone
Gearbox torqueNormal
Trends
Dashed line is the alarm or operating limitPump fillage0 %
Minimum 55 %
Peak rod load0.0 klbs
Limit 24 klbs
Strokes per minute0.0 SPM
Max 10 SPM
Motor current0.0 A
Alarm 30 A
Production
Current oil
74bbl/d
VFM estimate
Potential oil
88bbl/d
Model estimate
Realization
84%
Current ÷ potential
Production gap
14bbl/d
420 bbl over 30 days
Actual vs potential · 7 days
● Actual ● PotentialWhere the gap comes from
14 bbl/dPump fillage8
Pumping speed3
Gas interference1
Downtime and trips1
Losses are estimated by the optimization and diagnostics models.