FieldEast Webb
Data flowing · 2 of 14 wells late or silent
Sample data · mock-up 7
OP

EW6650

Overview · Pad D · East Webb
Rod pump Warning
Live · updated 08:08:03
Oil rate (VFM)
61bbl/d
78% water cut
Liquid rate (VFM)
271bbl/d
Gas 35 Mcf/d
Strokes per minute
7.5SPM
Stroke length 120 in
Pump fillage
48%
Minimum 55 %
Peak rod load
21.4klbs
Limit 24 klbs
Motor current
25.9A
Alarm 30 A

Health

Warning
Failure window
35–60 days
Open health

Active alarms

Events
Warning1 h agoPump fillage low48 % (limit 55 %)

Optimization

Open
Strokes per minute
7.5 SPM → 6.2 SPM
Predicted change -5 bbl/d · nothing is applied until approved.

PlexPilot insight

Assistant
The pump is only filling 48% of its stroke, so the unit is stroking faster than the well can supply. Slowing to 6.2 SPM should remove the fluid pound.

Live operation

Dynamometer cards · surface and pump

Latest stroke, updated each cycle
Pumping unit
Strokes per minute7.5
Effective pump stroke48 %
Peak rod load21.4 klbs
Fluid poundDetected
Gearbox torqueNormal

Production

Current oil
61bbl/d
VFM estimate
Potential oil
106bbl/d
Model estimate
Realization
57%
Current ÷ potential
Production gap
45bbl/d
1,350 bbl over 30 days

Actual vs potential · 7 days

● Actual ● Potential

Where the gap comes from

45 bbl/d
Pump fillage
16
Pumping speed
11
Gas interference
11
Downtime and trips
7
Losses are estimated by the optimization and diagnostics models.
An unhandled error has occurred. Reload 🗙

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.