EW2260
Virtual flow meter · Pad B · East Webb
ESP
Critical
Model: pump curve + discharge pressure
Well setting: measured discharge pressure
Calibrated Oct 17 · well test
Using calculated methodDischarge sensor reading is flat and was excluded. Reporting from the calculated method until the sensor is fixed.
Reporting rate
1,451bbl/d
Calculated discharge pressure
Measured method
—bbl/d
Not available
Calculated method
1,451bbl/d
± 87 bbl/d
Methods differ
—%
+86 psi discharge
Method A · Measured discharge pressure
Configured · not runningNot availableDischarge sensor reading is flat and was excluded
Liquid rate
—bbl/d
Oil
—
Water
—
Gas Mcf/d
—
Discharge pressure · sensor
1,861 psi
Pump head
—
Intake pressure414 psi
Discharge pressure sensorFlat reading
Drive frequency53.6 Hz
Method B · Calculated discharge pressure
ReportingLiquid rate
1,451bbl/d
± 87 bbl/d
Oil
306
Water
1,145
Gas Mcf/d
402
Discharge pressure · calculated
1,947 psi
Pump head
3,513 ft
Wellhead pressure160 psi
Fluid gradient used0.451 psi/ft
Pump setting depth3,967 ft
Water cut (last test)78.9 %
Liquid rate · both methods
● Measured ● Calculated ● Well test ■ ±6% band on the reporting methodDischarge pressure · measured vs calculated
The gap between the lines is the error in the calculation (or a sensor problem)Well test comparison
Test dateMeasuredMethod AMethod BA errorB error
Oct 171,437—1,451
—+1.0%
Oct 101,480—1,451
—-2.0%
Oct 31,422—1,451
—+2.0%
Sep 261,466—1,451
—-1.0%