EW4410
Overview · Pad E · East Webb
Rod pump
Normal
Live · updated 08:37:49
Oil rate (VFM)
69bbl/d
77% water cut
Liquid rate (VFM)
295bbl/d
Gas 38 Mcf/d
Strokes per minute
6.2SPM
Stroke length 120 in
Pump fillage
78%
Minimum 55 %
Peak rod load
17.4klbs
Limit 24 klbs
Motor current
20.9A
Alarm 30 A
Health
NormalActive alarms
EventsNo active alarms on this well.
Optimization
OpenStrokes per minute
6.2 SPM → 6.6 SPM
Predicted change +1 bbl/d · nothing is applied until approved.
PlexPilot insight
AssistantNo anomalies on EW4410. All signals are inside their normal bands and the health score is 82.
Live operation
Dynamometer cards · surface and pump
Latest stroke, updated each cyclePumping unit
Strokes per minute6.2
Effective pump stroke78 %
Peak rod load17.4 klbs
Fluid poundNone
Gearbox torqueNormal
Trends
Dashed line is the alarm or operating limitPump fillage0 %
Minimum 55 %
Peak rod load0.0 klbs
Limit 24 klbs
Strokes per minute0.0 SPM
Max 10 SPM
Motor current0.0 A
Alarm 30 A
Production
Current oil
69bbl/d
VFM estimate
Potential oil
82bbl/d
Model estimate
Realization
85%
Current ÷ potential
Production gap
13bbl/d
390 bbl over 30 days
Actual vs potential · 7 days
● Actual ● PotentialWhere the gap comes from
13 bbl/dPump fillage8
Pumping speed3
Gas interference1
Downtime and trips1
Losses are estimated by the optimization and diagnostics models.