FieldEast Webb
Data flowing · 2 of 14 wells late or silent
Sample data · mock-up 7
OP

EW4410

Optimization · Pad E · East Webb
Rod pump Normal
Objective: maximize oil rate within equipment and process constraints

Recommended setpoint · Strokes per minute

Recommended 6.6 SPM
Current
6.2 SPM
→
Selected
6.6 SPM
Predicted oil
70 bbl/d
Change
+1 bbl/d

Scenarios

Compare options before you decide

Constraint check at selected setpoint

Calculated by the lift model
ConstraintNowPredictedLimitResult
Peak rod load17.3 klbs17.7 klbs≤ 24.0 klbsWithin limit
Pump fillage79 %75 %≥ 55 %Within limit
Motor current20.9 A22.2 A≤ 30.0 AWithin limit
An operator approves the change before it reaches the controller.