EW4432
Overview · Pad C · East Webb
ESP
Normal
Live · updated 08:36:43
Oil rate (VFM)
439bbl/d
71% water cut
Liquid rate (VFM)
1,513bbl/d
Gas 353 Mcf/d
Frequency
54.0Hz
Setpoint 54.0 Hz
Motor current
37.0A
Alarm 45 A
Intake pressure
608psi
Minimum 350 psi
Motor temperature
209°F
Alarm 245 °F
Health
NormalActive alarms
EventsNo active alarms on this well.
Optimization
OpenFrequency
54.0 Hz → 57.5 Hz
Predicted change +37 bbl/d · nothing is applied until approved.
PlexPilot insight
AssistantNo anomalies on EW4432. All signals are inside their normal bands and the health score is 88.
Live operation
Pump performance · live operating point
Head, power and efficiency vs. flow at 54.0 HzESP string
Surface VSD54.0 Hz
Discharge pressure2,063 psi
Pump · 280 stages3,385 ft
Intake pressure608 psi
Seal · protectorNormal
Motor temperature209 °F
Position in rangeInside range
Trends
Dashed line is the alarm or operating limitIntake pressure0 psi
Minimum 350 psi
Motor current0.0 A
Alarm 45 A
Motor temperature0 °F
Alarm 245 °F
Vibration0.00 g
Alarm 0.50 g
Production
Current oil
439bbl/d
VFM estimate
Potential oil
490bbl/d
Model estimate
Realization
90%
Current ÷ potential
Production gap
49bbl/d
1,470 bbl over 30 days
Actual vs potential · 7 days
● Actual ● PotentialWhere the gap comes from
49 bbl/dNot at optimal frequency29
Gas interference10
Low intake pressure5
Downtime and trips5
Losses are estimated by the optimization and diagnostics models.