FieldEast Webb
Data flowing · 2 of 14 wells late or silent
Sample data · mock-up 7
OP

EW4432

Optimization · Pad C · East Webb
ESP Normal
Objective: maximize oil rate within equipment and process constraints

Recommended setpoint · Frequency

Recommended 57.5 Hz
Current
54.1 Hz
→
Selected
57.5 Hz
Predicted oil
477 bbl/d
Change
+36 bbl/d

Scenarios

Compare options before you decide

Constraint check at selected setpoint

Calculated by the lift model
ConstraintNowPredictedLimitResult
Motor current37.1 A40.6 A≤ 45.0 AWithin limit
Intake pressure613 psi565 psi≥ 350 psiWithin limit
Motor temperature209 °F217 °F≤ 245 °FWithin limit
An operator approves the change before it reaches the controller.