EW7788
Virtual flow meter · Pad C · East Webb
ESP
Normal
No data
No data from EW7788 for 119 min. Values shown are the last known. Source: Controller offline · radio link down at Pad C
Open diagnostics
Model: pump curve + discharge pressure
Well setting: calculated discharge pressure
Calibrated Oct 17 · well test
Reporting rate
979bbl/d
Calculated discharge pressure
Measured method
—bbl/d
Not available
Calculated method
979bbl/d
± 59 bbl/d
Methods differ
—%
Calculated vs measured
Method A · Measured discharge pressure
Not availableNo discharge pressure sensor on this well
Liquid rate
—bbl/d
Oil
—
Water
—
Gas Mcf/d
—
Discharge pressure · sensor
—
Pump head
—
Intake pressure650 psi
Discharge pressure sensorNone
Drive frequency48.1 Hz
Method B · Calculated discharge pressure
ReportingLiquid rate
979bbl/d
± 59 bbl/d
Oil
295
Water
684
Gas Mcf/d
205
Discharge pressure · calculated
2,200 psi
Pump head
3,616 ft
Wellhead pressure145 psi
Fluid gradient used0.442 psi/ft
Pump setting depth4,645 ft
Water cut (last test)69.9 %
Liquid rate · both methods
● Measured ● Calculated ● Well test ■ ±6% band on the reporting methodDischarge pressure · measured vs calculated
The gap between the lines is the error in the calculation (or a sensor problem)Well test comparison
Test dateMeasuredMethod AMethod BA errorB error
Oct 17969—979
—+1.0%
Oct 10998—979
—-2.0%
Oct 3959—979
—+2.0%
Sep 26988—979
—-1.0%