EW7788
Optimization · Pad C · East Webb
ESP
Normal
No data
No data from EW7788 for 87 min. Values shown are the last known. Source: Controller offline · radio link down at Pad C
Open diagnostics
Recommended setpoint · Frequency
Recommended 51.0 HzCurrent
47.7 Hz
→
Selected
51.0 Hz
Predicted oil
318 bbl/d
Change
+23 bbl/d
Scenarios
Compare options before you decideConstraint check at selected setpoint
Calculated by the lift modelConstraintNowPredictedLimitResult
Motor current30.0 A33.2 A≤ 45.0 AWithin limit
Intake pressure657 psi611 psi≥ 350 psiWithin limit
Motor temperature198 °F205 °F≤ 245 °FWithin limit
An operator approves the change before it reaches the controller.