EW9012
Overview · Pad D · East Webb
ESP
Shut-in
Live · updated 08:35:57
Oil rate (VFM)
0bbl/d
No flow
Liquid rate (VFM)
0bbl/d
Gas 0 Mcf/d
Frequency
0.0Hz
Stopped
Motor current
0.0A
Alarm 45 A
Intake pressure
720psi
Minimum 350 psi
Motor temperature
140°F
Alarm 245 °F
Health
Shut-inActive alarms
EventsOptimization
OpenFrequency
0.0 Hz → 0.0 Hz
Predicted change +0 bbl/d · nothing is applied until approved.
PlexPilot insight
AssistantThe well tripped on underload. Gas interference is the most likely cause given the intake pressure history.
Live operation
Pump performance · live operating point
Head, power and efficiency vs. flow at 48.0 HzESP string
Surface VSDStopped
Discharge pressure2,701 psi
Pump · 280 stages4,608 ft
Intake pressure720 psi
Seal · protectorNormal
Motor temperature140 °F
Position in range—
Trends
Dashed line is the alarm or operating limitIntake pressure0 psi
Minimum 350 psi
Motor current0.0 A
Alarm 45 A
Motor temperature0 °F
Alarm 245 °F
Vibration0.00 g
Alarm 0.50 g
Production
Current oil
0bbl/d
VFM estimate
Potential oil
420bbl/d
Model estimate
Realization
0%
Current ÷ potential
Production gap
420bbl/d
12,600 bbl over 30 days
Actual vs potential · 7 days
● Actual ● PotentialWhere the gap comes from
420 bbl/dNot at optimal frequency21
Gas interference63
Low intake pressure42
Downtime and trips294
Losses are estimated by the optimization and diagnostics models.