FieldEast Webb
Data flowing · 2 of 14 wells late or silent
Sample data · mock-up 7
OP

EW9012

Overview · Pad D · East Webb
ESP Shut-in
Shut-inWell is shut in. Review the trip cause before restart.View alarm
Live · updated 08:35:57
Oil rate (VFM)
0bbl/d
No flow
Liquid rate (VFM)
0bbl/d
Gas 0 Mcf/d
Frequency
0.0Hz
Stopped
Motor current
0.0A
Alarm 45 A
Intake pressure
720psi
Minimum 350 psi
Motor temperature
140°F
Alarm 245 °F

Health

Shut-in
Failure window
Not estimated (shut-in)
Open health

Active alarms

Events
Critical1 h agoUnderload trip, well shut in12.1 A (limit 18.0 A)

Optimization

Open
Frequency
0.0 Hz → 0.0 Hz
Predicted change +0 bbl/d · nothing is applied until approved.

PlexPilot insight

Assistant
The well tripped on underload. Gas interference is the most likely cause given the intake pressure history.

Live operation

Pump performance · live operating point

Head, power and efficiency vs. flow at 48.0 Hz
ESP string
Surface VSDStopped
Discharge pressure2,701 psi
Pump · 280 stages4,608 ft
Intake pressure720 psi
Seal · protectorNormal
Motor temperature140 °F
Position in range—

Production

Current oil
0bbl/d
VFM estimate
Potential oil
420bbl/d
Model estimate
Realization
0%
Current ÷ potential
Production gap
420bbl/d
12,600 bbl over 30 days

Actual vs potential · 7 days

● Actual ● Potential

Where the gap comes from

420 bbl/d
Not at optimal frequency
21
Gas interference
63
Low intake pressure
42
Downtime and trips
294
Losses are estimated by the optimization and diagnostics models.
An unhandled error has occurred. Reload 🗙

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.