FieldEast Webb
Data flowing · 2 of 14 wells late or silent
Sample data · mock-up 7
OP

EW6034

Optimization · Pad D · East Webb
Gas lift Normal
Objective: maximize oil rate within equipment and process constraints

Recommended setpoint · Gas injection rate

Recommended 0.97 MMscf/d
Current
0.85 MMscf/d
→
Selected
0.97 MMscf/d
Predicted oil
281 bbl/d
Change
+16 bbl/d

Scenarios

Compare options before you decide

Constraint check at selected setpoint

Calculated by the lift model
ConstraintNowPredictedLimitResult
Casing pressure1,052 psi1,099 psi≤ 1,100 psiNear limit
Tubing pressure299 psi313 psi≤ 400 psiWithin limit
Lift-gas headroom0.35 MMscf/d0.23 MMscf/d≥ 0.00 MMscf/dWithin limit
An operator approves the change before it reaches the controller.