EW6034
Optimization · Pad D · East Webb
Gas lift
Normal
Recommended setpoint · Gas injection rate
Recommended 0.97 MMscf/dCurrent
0.85 MMscf/d
→
Selected
0.97 MMscf/d
Predicted oil
281 bbl/d
Change
+16 bbl/d
Scenarios
Compare options before you decideConstraint check at selected setpoint
Calculated by the lift modelConstraintNowPredictedLimitResult
Casing pressure1,052 psi1,099 psi≤ 1,100 psiNear limit
Tubing pressure299 psi313 psi≤ 400 psiWithin limit
Lift-gas headroom0.35 MMscf/d0.23 MMscf/d≥ 0.00 MMscf/dWithin limit
An operator approves the change before it reaches the controller.