EW5120
Optimization · Pad B · East Webb
Gas lift
Normal
Recommended setpoint · Gas injection rate
Recommended 0.92 MMscf/dCurrent
0.81 MMscf/d
→
Selected
0.92 MMscf/d
Predicted oil
252 bbl/d
Change
+14 bbl/d
Scenarios
Compare options before you decideConstraint check at selected setpoint
Calculated by the lift modelConstraintNowPredictedLimitResult
Casing pressure1,023 psi1,069 psi≤ 1,100 psiNear limit
Tubing pressure313 psi327 psi≤ 400 psiWithin limit
Lift-gas headroom0.35 MMscf/d0.24 MMscf/d≥ 0.00 MMscf/dWithin limit
An operator approves the change before it reaches the controller.